Is vitamin D affected by hemolysis? A clinical and laboratory perspective

4 min read

Hemolysis is the most common reason for blood sample rejection in clinical laboratories, representing a significant source of pre-analytical error. This process of red blood cell breakdown significantly impacts the accuracy of many blood tests, including those for 25-hydroxyvitamin D, potentially leading to a misdiagnosis of a patient's vitamin D status.

Quick Summary

Hemolysis, the rupture of red blood cells, causes interference in vitamin D blood tests, leading to inaccurate results. This interference, primarily from released hemoglobin, can falsely elevate measured vitamin D levels. Understanding the pre-analytical factors is crucial for laboratories and clinicians to ensure proper diagnostic interpretation.

Key Points

  • False Elevation: Hemolysis can cause a false increase in measured vitamin D levels, especially with automated immunoassay methods, potentially masking a true deficiency.

  • Assay Interference: The primary mechanism involves free hemoglobin released from red blood cells interfering with the optical and chemical processes of laboratory assays.

  • Method-Dependent Impact: Chromatography-based methods (LC-MS/MS) are less prone to hemolysis interference than antibody-based immunoassays.

  • Pre-analytical Error: Most hemolysis affecting blood tests is an in-vitro issue caused by improper sample collection and handling, which labs must detect to prevent inaccurate reporting.

  • Complex Clinical Picture: In chronic hemolytic diseases like sickle cell anemia, the relationship with vitamin D is more complex, with hemolysis potentially affecting vitamin D metabolism in-vivo.

  • Patient Impact: A falsely elevated vitamin D result from a hemolyzed sample could prevent a patient from receiving necessary vitamin D supplementation.

  • Prevention is Key: Following best practices for blood drawing, handling, and storage is the most effective way to prevent in-vitro hemolysis and ensure accurate lab results.

In This Article

Hemolysis is the premature breakdown of red blood cells, releasing their intracellular contents, including hemoglobin, into the surrounding plasma or serum. This event, whether caused by improper sample collection or an underlying medical condition, can significantly interfere with laboratory assays designed to measure various biomarkers. In the context of vitamin D testing, this interference is a critical concern, as inaccurate results can lead to inappropriate clinical decisions regarding supplementation or disease management.

The Mechanisms Behind Hemolysis Interference

When red blood cells rupture, the released components can disrupt vitamin D testing in several key ways:

  • Optical Interference: Hemoglobin, the red protein responsible for carrying oxygen, has a strong light absorbance at specific wavelengths. Many automated immunoassays used for measuring 25-hydroxyvitamin D rely on spectrophotometry. The presence of free hemoglobin can alter the optical properties of the sample, leading to a falsely elevated result. The degree of this optical interference is often proportional to the severity of hemolysis.
  • Chemical and Binding Interference: The released intracellular contents, including enzymes and other proteins, can interfere with the chemical reactions central to many immunoassays. More specifically, studies have shown that released hemoglobin can competitively inhibit the uptake of vitamin D-binding protein (DBP) by renal cells, a crucial step in vitamin D metabolism. While this relates to in vivo hemolysis in conditions like sickle cell disease, the principle of protein-binding interference can also apply to in vitro assays.
  • Assay-Dependent Variability: Not all vitamin D assays are affected by hemolysis in the same way or to the same degree. Immunoassays, which use antibodies to bind to the vitamin D metabolite, are particularly susceptible to this kind of interference. More advanced methods, such as liquid chromatography-tandem mass spectrometry (LC-MS/MS), are generally more specific and less prone to interference from matrix effects like hemolysis.

In-Vitro vs. In-Vivo Hemolysis and Vitamin D

It is important to distinguish between hemolysis that occurs during or after blood collection (in-vitro) and chronic hemolysis that happens within the body (in-vivo).

  • In-Vitro Hemolysis: This is the more common laboratory issue, resulting from poor blood draw technique, excessive shaking, or improper storage. It leads to false test results and is the reason many samples are rejected. A falsely elevated vitamin D reading due to in-vitro hemolysis could mask a genuine deficiency.
  • In-Vivo Hemolysis: In chronic hemolytic conditions, such as sickle cell disease, the continuous breakdown of red blood cells has a direct physiological impact on vitamin D status. Research has shown that in pediatric sickle cell patients, serum 25-hydroxyvitamin D levels correlated with biomarkers of hemolysis, suggesting that chronic red blood cell destruction may play a role in vitamin D deficiency in this population. This points to a more complex, systemic relationship between hemolysis and vitamin D metabolism in chronic illness.

Comparison of Assay Performance

While LC-MS/MS is considered the gold standard for vitamin D testing, clinical labs often rely on more cost-effective and high-throughput automated immunoassays. The reliability of these different methods is affected differently by factors like hemolysis. Below is a comparison to illustrate the key differences:

Feature Immunoassays (e.g., CLIA) LC-MS/MS (Chromatography)
Principle Uses antibodies to bind and detect 25(OH)D Separates and quantifies vitamin D metabolites by mass
Sensitivity to Hemolysis High risk of interference due to optical and binding factors Low risk of interference due to separation step
Effect on Results Can produce falsely elevated values in hemolyzed samples Generally provides accurate results even with some matrix interference
Cost and Speed Less expensive, high throughput, faster turnaround More expensive, lower throughput, requires specialized equipment
Accuracy Prone to inter-assay variability and matrix effects Considered the most accurate method
Interferences Susceptible to interferences from other vitamin D metabolites and binding proteins Separates interfering compounds, improving specificity

Best Practices to Minimize Hemolysis

Preventing in-vitro hemolysis is critical for ensuring reliable vitamin D test results. The CDC and various laboratory guidelines provide best practices for blood collection and handling.

  • Use the correct needle size (20–22 gauge) for venipuncture.
  • Allow the venipuncture site disinfectant to dry completely before the draw.
  • Avoid vigorous mixing of the blood sample tubes.
  • Fill tubes with the correct volume to avoid an excessive concentration of anticoagulant.
  • Transfer blood gently down the side of the collection tube after a syringe draw.
  • Limit the tourniquet time to under one minute.
  • Centrifuge samples within the recommended time frame (e.g., 4 hours) after collection.
  • For delayed testing, transfer the serum to a cryovial and store it at the correct temperature.

Conclusion

Yes, vitamin D blood tests are affected by hemolysis. For laboratory-induced, in-vitro hemolysis, the primary impact is a pre-analytical error that can falsely elevate results, potentially masking a vitamin D deficiency. This is particularly true for automated immunoassay methods, which are more susceptible to the optical and binding interference caused by released hemoglobin. Conversely, chronic in-vivo hemolysis, such as that seen in sickle cell disease, can also alter vitamin D status physiologically by disrupting its metabolism. The most reliable vitamin D measurement method, LC-MS/MS, is less affected by these interferences, but is not always feasible for routine testing. Ultimately, proper blood sample collection and handling are paramount to ensuring accurate vitamin D test results and avoiding potential misdiagnosis. The Centers for Disease Control and Prevention offer resources on proper sample handling to minimize hemolysis.

Frequently Asked Questions

Hemolysis is the rupture of red blood cells, releasing hemoglobin and other intracellular components into the surrounding plasma or serum. This can occur either during or after blood collection (in-vitro) due to improper handling, or within the body (in-vivo) in certain medical conditions.

Hemolysis interferes with vitamin D tests, particularly immunoassays, through several mechanisms. The strong light absorption of released hemoglobin can cause optical interference, leading to falsely high readings. Additionally, released intracellular components can disrupt the specific binding reactions of the assay.

Yes. If a vitamin D test result is falsely elevated due to hemolysis, a clinician might mistakenly conclude that the patient has sufficient vitamin D levels, delaying or preventing appropriate treatment for a true deficiency.

No. Different types of assays have varying sensitivities to hemolysis. Automated immunoassays are generally more susceptible, whereas chromatography-based methods like LC-MS/MS are more specific and less prone to interference from a hemolyzed sample.

A blood sample can become hemolyzed due to several factors, including using an incorrect needle size, excessive suction during the draw, vigorous shaking of the tube, or improper storage temperatures. The use of IV starts for blood draws can also increase the risk.

If a vitamin D test result is flagged for hemolysis, the laboratory will often reject the sample and request a re-draw. This is the safest and most reliable course of action to ensure the accuracy of the result.

Yes, in cases of chronic in-vivo hemolysis, such as in sickle cell disease, the physiological effects can alter vitamin D metabolism. Research indicates a relationship between chronic red blood cell destruction and vitamin D deficiency in this population.

To minimize hemolysis, phlebotomists should use the correct needle gauge, allow the venipuncture site to dry completely, and fill tubes to the proper volume. Gentle handling and prompt processing of the sample are also crucial steps.

References

  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7
  8. 8
  9. 9
  10. 10