What is EER and how is it calculated?

4 min read

According to the U.S. Department of Energy, newer air conditioners use the more stringent EER2 rating, highlighting the importance of understanding the Energy Efficiency Ratio (EER) for evaluating energy efficiency. This metric helps consumers compare how effectively different AC units convert electricity into cooling.

Quick Summary

The Energy Efficiency Ratio (EER) measures an air conditioner's cooling capacity relative to its power consumption under standardized, peak-load conditions. A higher EER indicates a more energy-efficient unit, which can lead to reduced electricity costs.

Key Points

  • Definition: EER, or Energy Efficiency Ratio, measures an AC unit's cooling output in BTUs relative to its electrical input in watts under specific test conditions.

  • Calculation: The formula is EER = Cooling Capacity (BTU/hr) ÷ Power Input (Watts).

  • Benchmark: A higher EER number indicates a more energy-efficient air conditioner.

  • EER vs. SEER: EER is for peak-load efficiency, while SEER measures average performance over an entire cooling season.

  • Cost Savings: Choosing a high-EER unit can lead to significant long-term savings on utility bills due to reduced energy consumption.

  • Factors: Real-world performance can be affected by humidity, room size, and proper maintenance.

In This Article

Understanding the Energy Efficiency Ratio (EER)

EER, or Energy Efficiency Ratio, is a metric used to evaluate the efficiency of cooling equipment, particularly air conditioners and heat pumps, under specific, peak-load conditions. It is the ratio of a unit's cooling output in British Thermal Units per hour (BTU/hr) to the electrical power it consumes in watts (W). The higher the resulting EER number, the more cooling the unit provides for every watt of energy used, indicating greater energy efficiency.

Unlike other metrics like SEER (Seasonal Energy Efficiency Ratio), which measures performance over an entire cooling season with varying temperatures, EER is based on a fixed set of test conditions. Specifically, EER is calculated with an outdoor temperature of 95°F (35°C), an indoor temperature of 80°F (26.7°C), and a relative humidity of 50%. This makes it a reliable way to compare the performance of different units when they are operating at maximum capacity, such as on the hottest summer days.

How to Calculate EER

Calculating EER is a straightforward process once you know the two key figures: the cooling capacity in BTUs per hour and the power consumption in watts. Most manufacturers provide both of these numbers in their product specifications, often on the unit's energy label.

The EER Calculation Formula

The formula is as follows:

EER = Cooling Capacity (BTU/hr) ÷ Power Input (Watts)

Step-by-Step EER Calculation Example

Let's walk through an example to illustrate the process. Imagine you have a room air conditioner with the following specifications:

  • Cooling Capacity: 10,000 BTU/hr
  • Power Consumption: 1,200 watts

To find the EER, you simply divide the cooling capacity by the power input:

  • 10,000 BTU/hr ÷ 1,200 W = 8.33 EER

This tells you that for every watt of power supplied, the unit provides 8.33 BTUs of cooling capacity under standard test conditions. When comparing different units, you would select the one with the higher EER for better energy efficiency and lower long-term operating costs.

Factors Influencing EER

While the official EER rating is determined under controlled laboratory conditions, several real-world factors can affect an air conditioner's actual energy efficiency in a home or building.

  • Humidity: Higher humidity levels require more energy to dehumidify the air, which can lower a unit's overall efficiency.
  • Installation: An improperly sized or incorrectly installed unit may have to work harder, decreasing its effective EER.
  • Airflow: Blocked vents or dirty filters restrict airflow, forcing the system to consume more power to achieve the desired cooling, thus lowering efficiency.
  • Maintenance: Poor maintenance, such as not cleaning coils, can reduce heat transfer efficiency and lower the EER over time.
  • Room Characteristics: The level of insulation, number of windows, and amount of heat-generating appliances in a room all affect the unit's workload and performance.

EER vs. SEER: A Comparison Table

It is important to differentiate EER from SEER, another common energy efficiency rating. The key difference is the conditions under which they are measured. EER measures efficiency under a single, peak-load condition, whereas SEER measures seasonal performance.

Feature EER (Energy Efficiency Ratio) SEER (Seasonal Energy Efficiency Ratio)
Conditions Measured Fixed, peak-load conditions (95°F outdoor, 80°F indoor). Performance averaged over an entire cooling season with varying temperatures.
Best For Comparing maximum efficiency on the hottest days. Common for room air conditioners. Providing a more comprehensive view of year-round energy consumption. Common for central AC units.
Calculation Cooling Output (BTU/hr) ÷ Power Input (Watts). Total cooling output (BTU) ÷ Total electrical energy used (Wh) over a season.
Rating Scope A snapshot of efficiency at a specific, demanding point in time. A broader overview that accounts for various load conditions.

Why a High EER Matters

Opting for a high-EER air conditioning unit offers significant benefits beyond simple cooling. Firstly, it leads to tangible cost savings on utility bills because the unit uses less electricity to produce the same amount of cooling. This financial benefit is compounded over the long lifespan of the appliance. Secondly, high-EER units have a positive environmental impact by reducing overall energy consumption and greenhouse gas emissions. These benefits apply to both residential and commercial properties.

Finally, for homeowners, choosing a unit with a high EER provides reassurance of efficiency under the most demanding conditions, ensuring the system can reliably and cost-effectively cool your space when you need it most. For consumers, considering both EER and SEER, where applicable, allows for a more informed decision about both short-term performance and long-term energy costs.

Conclusion

In summary, understanding what EER is and how it is calculated is essential for making informed purchasing decisions about cooling systems. The Energy Efficiency Ratio provides a snapshot of an air conditioner's efficiency during peak-load conditions by dividing its cooling capacity in BTUs by its power consumption in watts. A higher EER number signifies a more energy-efficient unit, leading to lower operating costs and a reduced environmental footprint. By familiarizing yourself with this metric and how it compares to SEER, you can choose a cooling system that provides optimal comfort while maximizing energy savings.

For more information on energy efficiency standards for cooling systems, visit the U.S. Department of Energy's website.

Frequently Asked Questions

A higher EER is better. While ratings vary, units with an EER of 12 or more are generally considered highly efficient. For room air conditioners, newer standards like EER2 are now in place.

You can find the EER rating on the unit's energy label or in the user manual. If that information is unavailable, you can check the manufacturer's website for the specifications of your model.

Yes, a higher EER indicates that a unit provides more cooling for the same amount of electricity. This increased efficiency translates into lower energy consumption and reduced electricity bills, especially when the unit is operating at full capacity.

Not necessarily. EER is better for comparing peak performance, while SEER gives a more complete picture of a unit's overall efficiency throughout an entire cooling season with varying temperatures. Your choice depends on your climate and priorities.

EER is calculated under standardized laboratory conditions with an outdoor temperature of 95°F (35°C), an indoor temperature of 80°F (26.7°C), and 50% relative humidity.

To improve your unit's effective efficiency, ensure regular maintenance like cleaning filters and coils, and improve your home's insulation to reduce the cooling load. Proper sizing of the unit during installation also plays a crucial role.