Which filter do you use for TPN?

4 min read

According to the American Society for Parenteral and Enteral Nutrition (ASPEN), the filtration of parenteral nutrition is a critical safety measure to reduce a patient's exposure to particulate matter and potential pathogens. Selecting the correct filter depends largely on the composition of the TPN solution.

Quick Summary

The appropriate filter for TPN depends on whether lipids are present in the solution. Lipid-containing admixtures require a 1.2-micron filter, while lipid-free solutions can use a smaller 0.22-micron filter. Correct filter selection and proper technique are essential for patient safety, preventing particulate contamination, and maintaining solution sterility during infusion.

Key Points

  • 1.2 Micron Filter for Lipids: A 1.2-micron filter is required for TPN solutions containing lipids (3-in-1 admixtures) because its pore size allows the fat emulsion to pass through without clogging.

  • 0.22 Micron Filter for Lipid-Free Solutions: For TPN solutions without lipids, a finer 0.22-micron filter can be used to remove bacteria and particulate matter, but it will occlude if used with lipids.

  • Standardize to Reduce Error: To minimize the risk of administering the wrong filter, some institutions, following ASPEN guidance, use a 1.2-micron filter for all TPN formulations.

  • Prevent Complications: Filters are essential for removing precipitates and preventing contamination that could lead to vein irritation, phlebitis, or more serious vascular complications.

  • Replace Filters Regularly: TPN filters and administration sets must be changed with each new container, typically every 24 hours, to maintain sterility and function.

  • Monitor for Occlusion: Healthcare providers should consistently monitor the TPN line and filter for signs of clogging, which can indicate precipitation and requires filter replacement.

In This Article

Understanding the Role of Filters in TPN

Total Parenteral Nutrition (TPN) is a life-sustaining therapy for patients who cannot receive adequate nutrition through oral or enteral routes. Due to the complex nature of the solution, which can contain amino acids, dextrose, lipids, vitamins, and minerals, there is an inherent risk of particulate contamination and microbial growth. A filter is a crucial inline component of the administration set that helps mitigate these risks by capturing foreign particles and precipitates before they enter the patient's bloodstream. Particles can originate from various sources, including manufacturing contamination, incompatible drug precipitation, or even small pieces of glass or rubber from packaging.

The Importance of Filtration in TPN

  • Prevents Particulate Contamination: Filters trap particulate matter, such as glass fragments, drug precipitates, and rubber from vial stoppers, that could otherwise cause vein irritation, phlebitis, or even more severe complications like pulmonary emboli.
  • Enhances Sterility: While compounding should be done aseptically, filters provide an additional layer of protection by capturing potential microorganisms, which is particularly important for solutions containing dextrose and lipids that can support microbial growth.
  • Reduces Risk of Complications: Filtering helps prevent serious adverse events. Historically, there have been documented cases of patient harm linked to calcium-phosphate precipitates in unfiltered TPN solutions.
  • Minimizes Air Embolism Risk: Air-eliminating filters can help trap air bubbles in the line, preventing them from being infused into the patient.

Which Filter Do You Use for TPN? Choosing the Right Micron Size

The correct filter pore size is determined by the TPN solution's contents, specifically the presence of lipids. A lipid-containing TPN solution is often referred to as a "3-in-1" or Total Nutrient Admixture (TNA).

1.2-Micron Filter

This is the standard and most commonly recommended filter for TPN solutions that contain lipids. The 1.2-micron filter is large enough to allow the lipid emulsion droplets to pass through without clogging, while still being effective at trapping particulate matter and certain microorganisms like Candida albicans. Major professional organizations, including ASPEN, recommend using a 1.2-micron filter for all TPN solutions to standardize practice and minimize the potential for human error. For dedicated lipid emulsion infusions, a 1.2-micron filter is also appropriate.

0.22-Micron Filter

The 0.22-micron filter is a sterilizing-grade filter designed to remove bacteria and fungi. It can be used for aqueous (lipid-free) TPN solutions, which contain only dextrose, amino acids, and other water-soluble components. Crucially, this filter should never be used for TPN solutions containing lipids, as the small pore size would trap the lipid particles, leading to filter occlusion and a disruption of the infusion.

Choosing Between Filter Types

  • For all-in-one TPN (with lipids): Use a 1.2-micron filter.
  • For lipid-free TPN: Use a 0.22-micron filter, or a 1.2-micron filter as per standardized hospital protocol.
  • For separate lipid infusions: Use a 1.2-micron filter.

Comparison of TPN Filter Types

Feature 1.2 Micron Filter 0.22 Micron Filter
Primary Use Lipid-containing TPN (3-in-1, TNA), or all TPN based on modern guidelines. Aqueous, lipid-free TPN solutions only.
Micron Size 1.2 µm 0.22 µm
Lipid Compatibility Yes - Pores are large enough for lipid particles. No - Pores are too small and will clog.
Bacteria Filtration Filters some larger bacteria like Candida albicans, but is not a sterilizing-grade filter. Acts as a sterilizing-grade filter, capturing most bacteria and fungi.
Particulate Removal Effective at removing precipitates and larger particulates. Highly effective for all particulates, but not for lipids.
Clogging Risk Low risk with proper use and hang time limits. High risk if used with any lipid solution.
Clinical Practice Often standardized for all TPN to avoid errors. Used specifically for lipid-free infusions or where extra sterility is needed.

Best Practices for TPN Filtration

To ensure maximum patient safety, several best practices should be followed when administering TPN with a filter:

  • Replace Regularly: Filters and administration sets should be changed with each new TPN container, typically every 24 hours, or as per manufacturer instructions.
  • Check Hang Time: Adhere to the recommended hang times for TPN, which is often 24 hours for all-in-one admixtures. For separate lipid infusions, hang time should not exceed 12 hours.
  • Inspect and Monitor: Always inspect the solution for any signs of emulsion instability or precipitation before infusion. Monitor the filter during administration for signs of clogging.
  • Follow Facility Protocol: Clinical guidelines from organizations like ASPEN and INS are crucial, but always follow your specific institutional policies and procedures.
  • Standardize Practice: Adopting a single filter size, such as the 1.2-micron filter for all PN, can simplify protocols and reduce the potential for medication errors.

Conclusion

For TPN administration, the choice of filter is dictated by the solution's composition. A 1.2-micron inline filter is the recommended standard for any TPN solution containing lipids, effectively removing particulates and maintaining the integrity of the fat emulsion. For lipid-free solutions, a 0.22-micron filter can provide a higher level of sterility, though some institutions standardize to a 1.2-micron filter for all TPN to prevent potentially dangerous mistakes. Regardless of the filter choice, consistent adherence to best practices, regular filter replacement, and close monitoring are paramount to ensuring patient safety and the effective delivery of nutritional therapy.

Learn more about ASPEN's filter recommendations for parenteral nutrition

Frequently Asked Questions

The primary purpose of a TPN filter is to prevent particulate matter, precipitates (like calcium-phosphate), and microorganisms from entering the patient's bloodstream, thus reducing the risk of complications such as phlebitis and infection.

A 1.2-micron filter should be used for all TPN solutions that contain lipids, also known as 3-in-1 or Total Nutrient Admixtures (TNA). Some guidelines also recommend its use for all PN solutions to standardize practice.

No, a 0.22-micron filter should never be used for TPN solutions containing lipids. The small pore size will trap the lipid emulsion particles, causing the filter to clog and stop the infusion.

According to typical protocols, TPN filters and the administration set should be replaced every 24 hours with each new TPN container. For dedicated lipid infusions, the set and filter are often changed every 12 hours.

If a TPN filter becomes clogged, the infusion will slow down or stop completely, potentially triggering an alarm on the infusion pump. The clogged filter must be immediately replaced with a new, correctly sized filter.

The in-line filter is typically placed as close to the catheter hub as possible to maximize protection against contaminants. Correct placement and priming are vital, and it should be positioned vertically during priming.

Administering unfiltered TPN increases the patient's exposure to particulate matter and potential microorganisms. This can lead to phlebitis, infections, and potentially severe adverse events from precipitates entering the bloodstream.

References

  1. 1
  2. 2
  3. 3
  4. 4